Wet Collector (Wet Scrubber)
For safe capture and collection of combustible dusts from working of aluminum, magnesium, titanium or similar metals/materials
General Specifications
| |
- Construction to be of 12 gauge for all metal surfaces that are in contact with water, other construction to be 14 gauge.
|
| |
- Motor and Blower to be of Plug Fan design, direct drive, TEFC motor, backward inclined wheel design of steel or aluminum construction. Non sparking.
|
| |
- Impeller to have at least a double (twice) water reversal design and have a minimum of 3”to 4”of pressure loss (w.g.)
|
| |
- Sludge Collection Tub to be angled and have clear access for removal of sludge.
|
| |
- Manual water level to be clearly marked by white plastic plate (unit blower off).
|
| |
- Following Impeller (in direction of air flow) shall be an after-filter/ mist eliminator combination constructed of polyester or other equal water resistant material. This shall be enclosed in a metal frame that provides rigid support for the filters.
|
| |
- Blower outlet chamber shall be lined with minimum of ½”closed cell poly foam.
|
| Equipment Options |
- Electronic Water Level Control assures optimum water level rangefor best performance. Also shuts down blower operation if water level exceeds upper or lower level safety set points
- Magnesium constant ventilation fan design to allow for exhausting of tub 24/7 once magnesium dust is present. Electrical controls to control this design are to be part of the equipment to meet NFPA regulations.
|